What is the impact of the power failure of the freezer?

2019-12-172072
First, frequent power outages will cause some damage to the freezer at the next startup.
1. Frequent power failures are very harmful to the freezer. When the freezer is suddenly closed during normal operation, it takes at least 5 minutes to turn on, which will affect the life of the compressor.
2. The freezer is not a problem when it is not working, but if the compressor is suddenly turned off and immediately powered on, the thermal protection is stopped because the freezer does not work because the pressure difference between the two ends of the compressor is very large. If the cryo-protected area is damaged, the engine may be burned.

Secondly, long-term parking of refrigerators should pay attention to these tasks.
1. If the energy has not been energized for a long time, the refrigerant will change from a gaseous state to a liquid state during operation, which will cause pipeline damage and cause leakage. The effect will be very bad on the next cool down.
2. Allow the freezer to extend its service life better. It is important not to let the commercial freezer shut off frequently.
3. When using the refrigerator again, perform the corresponding inspection and cleaning work.

If the freezer is re-enabled after a long period of time, what are the dangers, what should I watch out for and how to fix and resolve the problem?
Dangerous after long periods of inactivity.
1. The long-term deactivation of the refrigerator will cause the lubricant in the compressor to sink to the bottom, and all the workpieces in the machine will dry. At this point, if it is turned on, the compressor piston will run without lubrication, which will affect the life of the compressor. This will cause economic losses.
2.How to start a long-term decommissioned freezer
When restarting the freezer or refrigerator after a long period of inactivity, three instant startups are required. The specific method is: connect the power and then disconnect, repeat every 5 minutes, turn on and off 3 times in total.
3.Recommendations for freezer
If you find abnormal noise or shutdown after initial startup, if you cannot recover from refrigeration or leakage, you should ask a regular company professional for repair. Do not disassemble and repair by yourself, so as not to expand the fault scope.